GE Digital Energy
GE Digital Energy, a division of GE is a global leader in the design, manufacture, sales and support of protection, control, metering, communications, and automation systems, for utility, industrial, commercial and transportation applications.
- 1-877-605-6777
678-844-6777 - 2018 Powers Ferry Road
Atlanta,, GA, 30339
United States
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
HardFiber System
IEC 61850
The HardFiber System is a KEMA tested IEC 61850 Process Bus Solution that allows the mapping of measurements made in the switchyard to protection relays located in the control house using secure communications. The HardFiber System addresses the key technical and logistic challenges affecting the labor required for substation design, construction and maintenance.
-
product
Motor Protection Relay
239
The 239 relay is designed to fully protect three phase AC motors against conditions which can cause damage. In addition to motor protection, therelay has features that can protect associated mechanical equipment, give an alarm before damage results from a process malfunction, diagnose problemsafter a fault and allow verification of correct relay operation during routine maintenance.
-
product
Communication Converter
F485
The F485 is a self-contained device for converting between RS232, RS485 and fiber optic signals. The F485 is electrically isolated to improve communications in noisy environments. The converter uses internal switches to select the signal conversion type and communication rates up to 57600 bps. The F485 converter uses the data on the serial ports to determine direction and therefore requires no hardware handshaking signals from the computer.
-
product
Incremental Transformer Solutions
TRANSPORT X
The Kelman TRANSPORT X is a compact portable Dissolved Gas Analysis (DGA) system which can be used to analyze oil samples for all dissolved fault gases and moisture. If abnormal levels are detected, it further provides a diagnostic using various IEEE/IEC approved interpretation rules.
-
product
Power Quality Meter
EPM 9450
The EPM 9450 is the entry point for GE's premium 9000 meter series with advanced power quality capability. The unit utilizes ACCU-Measure Technology to provide highly accurate revenue grade readings coupled with advanced data analysis. The unit measures over 15,000 electrical parameters including real time harmonics to the 127th order, voltage surges and sags and a large assortment of advanced monitoring functionality.
-
product
Digital Power and Energy Measurement
EPM 2200
The EPM 2200 meter measures more than 40 electrical power parameters providing a low-cost, multifunction monitoring solution for industrial and power generation applications. EPM 2200 can easily be mounted in a panel for generator monitoring, substation automation and more. The meter can also provide data to RTUs, PLCs and other control devices.
-
product
USB-to-Serial Cable Converter
This cable is the solution for users who want to communicate with GE Multilin IEDs via PCs that have USB communication ports. Using this cable is quick and easy. Simply install the cable driver on your PC, plug in the cable and you are ready to communicate.
-
product
Compact Unmanaged Ethernet Switch
ML600
The MultiLink ML600 is a Compact Unmanaged Ethernet Switch that is ideal for Industrial Facilities, Substations, and Transportation environments that have few Ethernet devices in one location. As a very cost effective solution, the ML600 will supply you with high speed networking in your harsh environments and is equipped with Link Loss Learn (LLL) that allows for use in redundant architectures thus ensuring you will always have access to your devices.
-
product
Advanced Line Protection System
ALPS
ALPS is a multi-function digital protective relay system intended toprovide distance protection for HV or EHV transmission lines. It maybe applied on or adjacent to series compensated lines. It is availablefor single or three phase tripping applications. Typical operatingtimes are to 1 cycle.
-
product
Test Blocks & Plugs
PK-2
Type PK-2 test blocks are essentially 4-pole and 6-pole jacks, provided with molded Textolite covers that have internal plug contacts, which make a through connection when the cover is in place. The contacts in the blocks are of the line-pressure type and provide positive contact with minimum contact resistance.
-
product
19" Rack Mountable hardenedManaged Ethernet Switch
ML2400
The MultiLink ML2400 is a 19" Rack Mountable hardenedManaged Ethernet Switch that is designed specifically foruse in Industrial Facilities, Substations and Transportation environments. It will supply you with reliable, high-speednetworking of all your mission critical applications andprovide flexibility and security with easy to usemanagement functions that are unsurpassed in the industry.
-
product
8-Gas On-Line Transformer Gas Analyser
TRANSFIX
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
Bus Differential System
B90