Network Technologies Inc
Network Technologies Inc (NTI), based in Aurora, OH (USA), is a leading global provider of high quality IT infrastructure management solutions. NTI products are used worldwide by leading companies in every industry, including manufacturing, retail, government, education, healthcare, financial services, entertainment, worship, broadcast, and telecommunications.
- 800-742-8324
330-562-7070 - 330-562-1999
- sales@ntigo.com
- 1275 Danner Dr.,
Aurora, OH 44202
United States
-
product
Day/Night IP Surveillance Camera
ENVIROMUX-IPCAM-N
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
product
Carbon Dioxide Sensor, CO2
ENVIROMUX-CO2
CO2 room sensor for periodically unoccupied areas. Measures CO2 in a range of 0 to 2,000 ppm. 0 to 5 VDC output. Continuous automatic air pressure compensation. LED indicators for operation status and system test. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: RoHS.
-
product
5VDC Sensor Converter, 5VDC, 15mA
ENVIROMUX-S5VDC-5V
External RJ45 device monitors up to two linear DC sensors, 0VDC ~ 5VDC. Output for each sensor: 5VDC, 15mA. Connector: Screw Terminal, 8-position. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Includes Mounting Hardware. Powered by ENVIROMUX-2D/5D/16D. MTBF: 1,956,288 hrs. Compatible with ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS.
-
product
USB Extender via CAT5 to 200 Feet
USB-C5-200
The USB-C5-200 extends up to four self-powered or bus-powered USB devices to 200 feet. The USB extenders consist of two units, the local unit and the remote unit, which are interconnected with CAT5/5e/6/7 cable.
-
product
5VDC Sensor Converter, 12VDC, 25mA
ENVIROMUX-S5VDC
External RJ45 device monitors up to two linear DC sensors, 0VDC ~ 5VDC. Output for each sensor: 12VDC, 25mA. Connector: Screw Terminal, 8-position. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Includes Mounting Hardware. Powered by ENVIROMUX-2D/5D/16D. MTBF: 1,956,288 hrs. Compatible with ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS.
-
product
Rugged Door Contact Sensor
ENVIROMUX-DCSR
Monitors access with a magnetic bridge sensor (no special inserts necessary). Ideal for commercial and industrial installations in harsh environments. Heavy-cast aluminum housing with 18-inch stainless steel armored cable. Floor-mounting hardware included. For normally open or normally closed circuit connection. Wide actuating gap, approximately 3". Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH (in): Magnet: 3.5x1.5x1.5 (89x38x38 mm), Switch: 3.5x1.5x0.44 (89x38x11 mm). Regulatory approvals: UL.
-
product
4-20mA Sensor Converter
ENVIROMUX-S420MA-24V
External RJ45 device monitors up to two 4-20 mA analog sensors. Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors. Provides 24VDC, 25mA for each sensor. Connector: Screw Terminal, 8-position. Supports CAT5/5e/6 cable up to 500 ft. (152 m). Includes Mounting Hardware. Powered by ENVIROMUX-2D/5D/16D. Compatible with ENVIROMUX-2D/5D/16D. Regulatory approvals: RoHS.
-
product
Smoke Detection Sensor - UL Approved, TAA Compliant
ENVIROMUX-SDS-TAA
For warning of smoke. Photoelectric smoke detector. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Voltage Supply: 8-35VDC. Current Consumption: 200uA. Alarm Output: Relay (NO). Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL. TAA compliant.
-
product
Duct Mount Temperature/Humidity Sensor
ENVIROMUX-STHS-DCT
Combines excellent stability with easy installation and reliable operation. Duct Mount ENVIROMUX-STHS-DCT: Applications from 14 to 140°F (-10 to 60°C). Temperature accurate to within ±0.54°F (±0.3°C). Relative Humidity accurate to better than ±3% from 10 to 90% relative humidity at 68°F (20°C). Insensitive to dust and most chemicals. Requires the ENVIROMUX-S420MA-24V to operate. Maximum cable length: 500 ft (152m). Regulatory Approvals: CE, RoHS. Enclosure: IP65, NEMA 4.
-
product
IP Surveillance Camera
ENVIROMUX-IPCAM
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.0 mm (0.16 in). RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
product
CATx Surge Protector
SP-CAT5-6V
Protects sensors running on CATx unshielded twisted pair (UTP) cable against the effects of electrostatic discharge, faulty wiring and lightning. The use of two protectors on each end of the line will provide increased protection for each end against surges. Protected pins: (1,2) (3,6) (4,7) and (7,8) pass through. Impedance: 85 to 115 Ohms. Surge suppression: 22Vpeak @ 100A 10/1000µs. Maximum continuous voltage: 6Vpeak. Dimensions WxDxH: 1x3.6x0.9 in (25x91x23 mm). Regulatory approvals: GR 1089, NEC 800.100 and 830.100, ITU 703, UL94 V0 Flame Rated.
-
product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
product
Light Intensity Sensor
ENVIROMUX-LIS
Detects and measures the luminous intensity of light. Ideal for monitoring unmanned closets, telecom rooms, remote data rooms, or other low traffic facilities. Applications from 0 to 128,000 lux. Human eye response (540 nm peak sensitivity). IR and UV rejection. RJ45 connector. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS. Compatible with ENVIROMUX-2D/5D/16D.
-
product
DVI Video Matrix Switch with Audio Option up to 32x32
SM-nXm-DVI-LCD
The VEEMUX® DVI Video Matrix Switch routes video from up to 32 single link digital DVI video sources (computers, DVD players, satellite receivers, etc.) to up to 32 displays (LCD monitors, Plasma screens, DLP HDTVs, projectors, etc.) and stereo audio speakers (with audio option).
-
product
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
ENVIROMUX-SDS-120V
For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.