Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkey
-
product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
product
Harmonic Filter Resistors
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
High Resistance Neutral Grounding Devices
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
Iron Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
LCL Filters
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
product
Motor Starting Auto-Transformers
Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.
-
product
Motor Starting & Control Resistors
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
product
Motor Termination Units
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
product
Neutral Grounding Resistors
NGR
Neutral Grounding Resistors (NGRs) are used to limit the fault current for safety of equipment and personnel in industrial systems.
-
product
PLC Line Traps
Line Traps are used in transmission and distribution networks and they are the key components in Power Line Carrier (PLC) systems used for remote control signals, voice communication, remote metering and control between substations in the electrical T&D networks.
-
product
Air Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Air Core Electric Arc Furnace Reactors
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
product
Air Core Harmonic Filter Reactors
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.