Filter Results By:
Products
Applications
Manufacturers
Atmosphere
1) a planet's exosphere, surface to space, space. 2) a unit of atmospheric pressure.
See Also: Atmospheric, Air, Earth, Climate, Space
-
product
Dynamic Gas Analyser
ExQ
The Hiden ExQ quantitative gas analyser is a new multi-featured and compact mass spectrometer system providing continuous on-line analysis of dynamic gas streams at pressures from sub-atmospheric up to 30 bar, the fully integrated system now being configurable both for benchtop and for rack-mounting operation. Connection to the process is via a flexible heated inert capillary line with a sample consumption rate less than 10 mL/minute and a response time of less than 300 milliseconds at pressures near atmosphere. The comprehensive range of process interface options enables adaptation of the system to accommodate analysis of up to 16 individual process streams, and adaptors are available for direct connection of the system to most standard TGA/TA instruments. External process data, sample temperature or mass for example, can be imported for combined integration and presentation with the mass spectral data.
-
product
Reservoir Isolators
Fluid contamination can lead to high maintenance costs and downtime in hydraulic systems. Parker reservoir isolators provide protection against the ingestion of airborne contaminants such as dust, chemicals and water vapor through the breather-vent of your hydraulic system. Utilizing an elastomer bladder as a lung, the changes in gas volume in a hydraulic system's reservoir can be trapped and prevented from mixing with the outside atmosphere. Unlike conventional breather-vent filters, Parker reservoir isolators provide a positive separation without the possibility of clogging or need for maintenance.
-
product
Temperature Controlled Microscope Stage
Linkham Scientific Instruments
Specialists in temperature controlled microscopy, Linkam Scientific Instruments, announce the launch of their Optical DSC450 which enables simultaneous visualization of thermal processes for improved materials characterisation. The Optical DSC450 enables the user to measure glass transitions and melting behaviour of a wide range of substances whilst accurately controlling temperature from -196 °C to 450 °C. The atmosphere of the stage can also be purged with gas as required by the user. A new feature which will increase the characterisation capabilities of the DSC system is to combine it with imaging capability. The new LINK Digital Imaging module enables additional information to be obtained by correlating optical changes such as colour with temperature. The new TASC analysis tool takes this further. TASC (Thermal Analysis by Surface Characterisation) is a new image analysis capability which enables structural changes in samples to be tracked and quantified optically. It has the unique ability to measure local transition temperatures allowing different points on a sample to be identified. The new DSC system is great tool to use in research and quality control to measure quantitative values for glass transitions, melting peaks and sample purity and, when combined with TASC, even sample homogeneity.
-
product
High Pressure Gas Conditioners
HPG
Bemco HPG, High Pressure Gas Conditioners are similar to the PTS Portable Temperature Conditioners except they are designed for continuous operation at up to two atmospheres (29.4 psia) of pressure. This higher base operating pressure doubles the gas density per cfm of circulating air or gaseous nitrogen allowing the use of smaller connecting tubes while also increasing thermal capability. .
-
product
Short Range Detection Systems
The EFM-100 kit comes complete with a high accuracy short range detector, inverted mounting hardware, cables and adapters. It is designed to provide a real time reading of the electrical field in the atmosphere with a time vs e-field graph displayed on a computer along with lightning strike distances accurate to within one mile.
-
product
General Performance Differential Pressure Transducers
These general performance Baratron® differential capacitance manometers measure the difference in pressure between the inlet tube and the reference cavity. The reference cavity can be connected to any pressure or vacuum source, or be open to local atmosphere.
-
product
Portable Ethylene Analyzer
F-900
The F-900 Portable Ethylene Analyzer provides measurements of ethylene in real time. Quality Assurance professionals use the F-900 to collect the data they need to manage ethylene gas accurately and efficiently—in controlled atmosphere facilities, cold storage, and shipping containers.
-
product
Explosion-Proof Differential Pressure Switch
1950G
The Model 1950G Explosion-Proof Switch combines the best features of the popular Dwyer Series 1950 Pressure Switch with the benefit of natural gas compatibility. Units are rain-tight for outdoor installations, and are UL listed for use in Class I, Groups A, B, C, & D; Class II, Groups E, F, & G and Class III atmospheres, ATEX for EExd IIB & Hydrogen T6, and CSA & FM approved for Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G and Class III atmospheres
-
product
Vacuum Measurement
Agilent's full range of active and passive vacuum gauges and gauge controllers from atmosphere to UHV/XHV allow you to precisely and reliably control and measure vacuum. We offer Thermocouple (TC), Bayard Alpert (BA), Pirani, Inverted Magnetron (IMG), and Hot Filament (HFIG) gauges. Our gauge controllers are compatible with both Agilent and competitors' gauges and can handle up to 12 channels. Agilent controllers come with several communication interfaces including Profibus, ethernet, and RS-232/485 (other interfaces may be available upon request). There is also the option of a portable gauge controller (HGC-536).
-
product
Material Analysis Instrument
Thermogravimetric Analysis measures the amount and rate of change in the weight of a material as a function of temperature or time in a controlled atmosphere.
-
product
Thermogravimetric Analyzers
TGA THERMOSTEP ML
ELTRA's TGA Thermostep ML is a thermogravimetric analyzer which determinesvarious parameters such as moisture, volatiles and ash at user-definedtemperatures and atmospheres in a single analysis.
-
product
Gas Mixers
Get the right gas mixture and flow rate using our Gas Mixers for Modified Atmosphere Packages. We offer gas mixers for CO2, Oxygen, Nitrogen, and Argon gases.
-
product
Safety Relay, 4 Contacts, 10A
D-BW
The D-relays series are designed for demanding industrial applications such as power utilities and petrochemical industries. The construction of the relay and choice of materials makes the D-relay suitable to withstand corrosive atmosphere, low and high temperatures and vibrating environments. No external retaining clip needed as integrated ‘snap-lock’ will hold relay into socket under all circumstances and mounting directions All relays are equipped with a LED and suppression diode.
-
product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
product
*High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Photoelectric Direct Reading Spectrometer
TY-9610
Wuxi Tianmu Instrument Technology Co., Ltd.
1, Optical SystemStructure: Pa type - RungeRaster: Radius of curvature: 750mmIncident slit width: 20 μ mExit slit: high-precision photolithography of the entire slit, according to different elements set up 30u-75u slit width.Detector: Photomultiplier tube ( PMT ) detector2, all digital excitation light source1. Fully digital intelligent composite light source DDD technology, which can automatically adjust the excitation parameters of light source according to the excitation characteristics of different materials, and truly realize full digital control. 2. Using the all-digital control mode, high-energy pre-combustion technology ( HEPS ), ultra-stable energy release stimulates the sample in an argon atmosphere. 3. The application of all-digital light source improves the measurement accuracy and similarity of the sample, improves the sample excitation speed, improves the spark stability, and makes the sample have better reproducibility. The maximum discharge current reaches 400A .
-
product
Package Leak Detectors
Package leak detectors ensure that seal integrity problems are identified. This is a vital part of Modified Atmosphere Packaging (MAP) quality control, since compromising the protective atmosphere will cause a reduction in the shelf-life of MAP products.
-
product
Gas Analysis
HPR-20 DLS
The Hiden HPR-20 DLS gas analysis system is configured for continuous analysis of gases and vapours at pressures near atmosphere in standard form, alternative inlet systems being offered for applications requiring direct sampling from higher pressures to 30 bar.
-
product
SF6 Gas Detection Thermographic Camera
TC706
The TC706 displays and signals SF6 gas leaks, without the need to de-energize high-voltage equipment or stop operation. The portable camera also highly improves operator safety by detecting emissions at safe distances and helping to protect the environment by detecting the leakage of environmentally harmful gases into the atmosphere.
-
product
HV Rotary Switches
B-1003
A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use. In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation. G-7 silicone glass is used for special applications where RF or high temperatures are involved. Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force. This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions. Ratings to 150kV, to 200A. When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater. In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional). Each unit is either manually or electrically operated. One SPDT contact is standard on most units. The auxiliary contact is used as an interlock for protection against "Switching Hot".
-
product
High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Pressure Manometer
These devices indicate the difference between two pressures (differential pressure), or between a single pressure and atmosphere (gage pressure), when one side is open to atmosphere.
-
product
Ecosystem Monitoring
LI-COR provides solutions to monitor the core processes of an ecosystem—light, plants, soil, water, and atmosphere—and research their interdependencies.
-
product
Ozone Aging Test Chamber
Sanwood Environmental Chambers Co ., Ltd.
Sanwood , a 23 years of professional Ozone aging Chamber,Ozone aging Test Chamber, Ozone resistance test chamber, Ozone chamber,Ozone test chamber, manufacturersOzone Aging Test Chamber simulates and enhance the condition of ozone in the atmosphere to study the effects of ozone on rubber, and then identify and evaluate the method to resist ozone and aging for rubber, adopt effective anti-aging measures to enhance the life of rubber products.
-
product
Headspace MAP Gas Analyzers
Headspace analysis is conducted to ensure that the residual oxygen in a product complies with predefined limits. This is a vital part of the Quality Control of Modified Atmosphere Packaging (MAP) products. For packaged foods and other goods, exceeding these limits increases the risk of growth and proliferation of bacteria or mould, which causes spoilage and results in shorter product shelf-life.
-
product
Gas Analysis
HPR-20 TMS
The Hiden HPR-20 TMS Transient MS is configured for fast event gas analysis of gases and vapours at pressures near atmosphere. Ideal for fast gas switching experiments the MS features the Hiden QIC quartz-lined 0.9 m sampling interface.
-
product
ATEX-Compliant IR Temperature Sensors
FLIR A310 ex
Explosive atmospheres need to be protected from ignition sources. Selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations is essential. FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Typical applications for the A310 ex include process monitoring, quality control, and fire detection in explosive locations. Because the FLIR A310 ex is rated IP 67, it can be installed in dusty environments. The Flame-Proof Enclosure "d"prevents any explosion transmission from the inside of the enclosure to the outside.
-
product
Controlled Atmosphere
KP Technology offer a range of Kelvin Probes that work in a controlled environment including automatic control of relative humidity within the Kelvin Probe housing and integrated nitrogen atmosphere control.