Filter Results By:
Products
Applications
Manufacturers
Illuminance
amount of light striking a given surface or perceived brightness.
See Also: Illumination, Illuminance Meters, Illuminators
-
product
Illuminance Meter
B 520
Display range 0.0001 lx (last digit) to 600 000 lx. Photometer head P 30 SC0, 30 mm dia. light sensitive surface. Very fine V(lamda)-approximation, cos-correction.
-
product
Illuminance Meters
Konica Minolta Sensing Americas, Inc
Illuminance meter products are single element detectors that measure photometric brightness falling upon a surface. It is measured in footcandles or in lux. The Konica Minolta illuminance meters measure the amount of light that strikes a surface. These instruments display illuminance in either lux or foot-candles and they are lightweight, compact and portable.
-
product
Illuminance Probe
LP471PHOT
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
product
Illuminance Spectrometer
IM Series
There are various lineups to measure illuminance, chromaticity, color temperature and spectrum for various light source.
-
product
Illuminance Color Meters
Konica Minolta Sensing Americas, Inc
Illuminance Color Meters from Konica Minolta measure photometric brightness and also provide detailed color information for light readings.
-
product
Illuminance (lux) Probe
LPPHOT01
The LPPHOT01 probe measures illuminance (lux) defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m2).
-
product
Photometric Probe for Illuminance
LPPHOT02
Outdoor photometric probe for measuring ILLUMINANCE (0…150 Klux), CIE photopic filter, diffuser for cosine correction. mVdc output for klux. Complete with Calibration Report. On request 5 or 10m cables with connectors.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
Lux / Illuminance Meters
PeakTech Prüf- und Messtechnik GmbH
Iis a precise measuring device which is suitable for measuring the illuminance of LED lights, fluorescent or conventional filament lamps with different light colors. The measurement is carried out in lux (lx), foot candle (fc) or candela (cd). Simple lux meters are mostly only for the measurement of standard light e.g. Filament lamps with a color temperature of 2856 K are suitable and deliver inaccurate measurement results at different color temperatures.
-
product
Pocket Illuminance Meter
PHOTO-100
This Pocket Illuminance Meter has performance of high precision, low consumption, small volume, stable performance and convenience operation. It’s mainly used in industrial field for illumination photometry.
-
product
Compact Precision Illuminance Meters
B 360
Photometer head with cos-correction and 3 m connection cable and with very fine V(lamda)-approximation.
-
product
Spectral Color Illuminance Meter
HPCS-320
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
spectral color illuminance meter
-
product
Stroboscopic Illuminance Meter-APP Version
HPL-200 Series
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
The research level of photosynthetically active radiation (PAR), PPF and PPFD measures the PPFD measurement of the outdoor environment, the canopy of the plant in the greenhouse and the growth room, and the PPFD measurement of the reflection or under the canopy (transmission) in the same environment. Quantum sensors are also used to measure ppfd in water environments, including saltwater aquariums where corals grow.
-
product
Digital Colorimeter & Illuminance Meter
CHC-I
This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.
-
product
Pocket Colorimeter Illuminance Meter
HPC-3
Shenzhen Chuangxin Instruments Co., Ltd.
● Adopting micro-spectrometer technology which is more accurate than traditional photo-detectors .● Measure chromaticity coordinate temperature, chromaticity coordinate, rending index, color difference, etc● Data hold, save and open-function. Several groups of data can be saved. ● Accuracy of chromaticity coordinates :±0.003(x ,y)● 128*64 LED of graphic interface displaying spectrum wave, chromaticity diagram ● USB interface for PC communication ● Quality Li-Battery for recycled-utilization ● Range of wavelength:380nm-780nm; ● wavelength accuracy:±0.5nm Repeatability:±0.2nm ● Accuracy of chromaticity coordinate:±0.0025, Resolution:0.0001; ● Correlated color temperature:1500-25000K, Accuracy:±3%,Resolution:1K; ● Accuracy of total color difference:within±0.2 (under standard illuminate A); ● Range of Illumination measurement:1.0lx-100klx; ● Accuracy of Illumination measurement:Class 1
-
product
RGB Laser Illuminance, Luminance & Optical Power Meters
TM6102/TM6103/TM6104
Accurately evaluate the white balance of displays that use lasers by measuring centroid wavelength and optical power, which are key characteristics in the evaluation of laser light sources. Designed to adjust and inspect RGB lasers. Meters measure radiant illumination, centroid wavelength, illuminance, luminance, chromaticity, Radiant flux (optical power) and luminous flux.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
Handheld Portable Multifunction Data Logger
HD31
Three independent input channels Automatic recognition of the probes - Measurement of Temperature Relative Humidity Atmospheric and differential pressure Air Speed Illuminance (lux) and Irradiance Carbon dioxide (CO2) – Air Quality Direct voltage (VP473 module) and current (IP472 module).
-
product
Handheld Portable Spectrometers
The UPRtek line of precision portable spectrometers are reliable, lightweight and easy-to-use. These spectral illuminance (LUX) meters or spectral light meters from Gamma Scientific are designed for fast and accurate light measurement. This product collection includes ultra-compact, basic and advanced models. With both battery-operated and line-power modes, these portable spectrometers are particularly well suited for field and laboratory use.
-
product
Instrument Systems LED And Display Measurement
Konica Minolta Sensing Americas, Inc
Instrument Systems is a frontrunner in developing state-of-the-art light measurement equipment, software, and accessories, taking great pride in constructing products that provide fast, accurate readings to ensure precise data for laboratory, production and quality assurance testing. All Instrument Systems products have stringent quality and performance requirements to ensure that customers get the highest quality equipment. As a leading supplier world-wide, they provide cost-sensitive support to a diverse clientele to help them measure luminance, flux, intensity, illuminance, and chromaticity of LEDS, lamps and displays throughout all aspects of product development and production.
-
product
Light / Lux Meter, 100000 lx, 100 lx, 5 %, 180 mm, 72 mm, 32 mm
72-6693
The Tenma 72-6693 is a high accuracy Illuminance meter. Featuring a dual function display, this meter can record both maximum, minimum and average readings. User selectable lighting types of tungsten/sun, fluorescent, sodium and mercury.
-
product
Light Meter
MODEL 5202
Kyoritsu Electrical Instruments Works, Ltd.
Digital Light Meter 3 ranges changeable from low to high illuminance. (200/2000/20000lux) Data hold function. Digital light meter with separate light recieving sensor and meter.
-
product
Light Meters
LXP-2
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
product
Mobile Light Meter
BTS256-E
BTS256-E - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum. The BTS256-E is a high-quality light meter that is well suited for illuminance and luminous color measurements in all application areas thanks to its compact design, high-quality light sensor and precise cosine field of view function.
-
product
Multifunctional testers
MI 3102 BT EurotestXE
MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. It supports AUTO SEQUENCE® testing of the TN, TT and IT earthing systems. ISFL measurements and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Optical Meters
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
product
PHOTO-2000AH Automatic Horizontal Photometer
Hangzhou Everfine Photo-E-Info Co., LTD
PHOTO-2000AH is used to test the horizontal illuminance of sloping surfaces. It has the advantages of small size, easy operation, high precision, wide range and low power consumption, and is especially suitable for the lighting effect evaluation of sports venues, industrial sites, commercial lighting and other occasions.