Filter Results By:
Products
Applications
Manufacturers
Conducted Immunity
EUT's resilience to an injected disturbance through associated cable.
See Also: Immunity Test, Coupling Decoupling Network
-
product
Immunity
RF coupling
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
product
Inducitive Switch Transient Test Circuit
NSG 5071
The basic philosophy of this test circuit is better reproducibility of actual switching transients. The reproducibility of this test circuit comes not from the output characteristics as in traditional conducted automotive immunity tests, but from a fixed design of the generator using several pre-defined components. Many of these components are defined in the standard as "critical" with no substitutions allowed. These components are used as required in the standard.
-
product
RF Synthesiser
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests and 30MHz - 6GHz for radiated tests. They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
product
Automotive EMC test systems
Dozens of manufacturer's and other automotive immunity standards with their roots in ISO 7637 continue to evolve bringing new challenges to users of conducted immunity testing. Teseq continues to advance the state of the art, bringing simple, flexible solutions for the challenging and fast-changing requirements that are 42 V ready.Teseq has been at the forefront of the pioneering work to establish EMC tests for motor vehicle electronics. Automotive manufacturers and suppliers worldwide have come to trust test systems from Teseq. Active involvement in the standardization committees ensures that the latest advances are continously reflected in our test systems.
-
product
150 kHz-230 MHz Broadband Power Amplifiers
Output power up to 80W for standard conducted immunity testing. Our 150 kHz-230 MHz amplifier range covers output power ranging from 20 W to 80 W.
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
Coupling Decoupling Network
TBCDN-M3
The TBCDN-M3 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Network
TBCDN-M2
The TBCDN-M2 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
EMC Testing Knowledge & Equipment
Creating, delivering, installing, and training on EMC test systems; RF Immunity systems, RF Radiated and Conducted Emissions systems, Conducted Immunity and Pre-compliant EMC systems.
-
product
Coupling Decoupling Network
TBCDN-M1
The TBCDN-M1 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Network
TBCDN-M4
The TBCDN-M4 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Current Probes
Com-Power's Current Injection Probes are used for RF conducted immunity testing per IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160 and MIL-STD 461. Current injection Probes are to be used only when there is no commercially available CDN for the type of port(s) to be tested.
-
product
Multi-Tone Test Systems
AR RF/Microwave Instrumentation
AR’s state-of-the-art multi-tone systems are designed to test RF Radiated and Conducted Immunity faster than ever before. Both the MT2IEC10V3M and MT4IEC10V3M fully comply with IEC 61000-4-3:2020 Edition 4, allowing for multiple tone testing, reducing test time by up to 74%. Commercial, aviation, and automotive industries, will perform RF radiated and conducted immunity testing faster, more accurately, more efficiently, and more closely to a real-world environment.
-
product
RF Shielded Chamber
MIL-STD
A high performance RF-shielded chamber specifically designed for radiated emissions testing in accordance with MIL-STD-461E/F. This chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.
-
product
RF Conducted Immunity Testing
AR RF/Microwave Instrumentation
If you are tired of mixing and matching various components, try AR’s complete line of RF Conducted Immunity Test Systems. We now make one fully configured and standalone CI System from 4 kHz to 400 MHz with output powers designed to meet the latest commercial, custom, and military standards. In addition, AR provides configurable systems meeting your specific requirements of increased power and frequency range.
-
product
EMC Testing
Does your product send or receive electromagnetic data? This can be analyzed using various tests. We investigate the interference immunity and emitted interference of simple electrical devices and complex machinery. Our EMC measurements and tests conducted in accordance with standards recognize all activity in the electromagnetic field and ascertain how immune to interference a piece of equipment is. We will also offer guidance on optimizing the product in terms of its EMC properties during the development phase.
-
product
Automotive Supply Simulation System
Spitzenberger & Spies GmbH & Co. KG
The modularly constructed Automotive Supply Simulation System is a compact EMC-Test System for the execution of immunity measurements for pulse-shaped, line conducted disturbances at electronic equipment of motor vehicles. The high performance version enables tests of current-intense consumers or even complete vehicles
-
product
Conducted Immunity Test System
Conducted RF immunity tests acc. to IEC/EN61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL-STD 461 CS 114 Signal generator,RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-caseStand-alone operation possible with optional available netbookControl-software includedMost important parameters are shown on an integrated displayAutomatic EUT-monitoringOperation via USB port of a PC or NotebookComplete range of CDNs available
-
product
EMC Testing Services
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
product
ESD Protection
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
product
CDN - Coupling / Decoupling Networks
The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.
-
product
RF Conducted Immunity Test System
RFCI61000-4-6
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.