Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Matrix Module, 6x8, 2-Pole, Y Loop-thru
42-514-001
The 40-514-001 (PXI) and 42-514-001 (PXIe) are low density matrices in 6x8 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Four Channel Low-Noise DC Bias Card
PI-41702
The PI-41702 is a four channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V, and this card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output. Additionally there is a ‘D’ type connector that allows the introduction of laboratory type supplies to reduce the noise further. To change from using the internal power supplies to external power supplies requires repositioning jumpers. The PI-41702 also has voltage and current sense for remote measurement of the voltage and current levels.
-
product
High Current Probes
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
product
Operational Amplifier
Op Amp Series
The amplifier is capable of operating at supply voltages from 0.9V to 3V with specified specs at 1V and 1.8V single supply.The input common mode range extends to both power supply rails without the offset glitch and input bias current phase reversal inherent to most rail to rail input amplifiers.
-
product
O/E Converter
TIA-4000
The TIA-4000 is comprised of a fibre coupled InGaAs APD detector combined with a variable reverse bias voltage network and fast transimpedance amplifier. The output of the unit is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the transimpedance produces a voltage that is proportional to the light incident on the detector surface.
-
product
PIN Diodes
PIN photodiodes convert light to current – without a bias voltage having to be applied. Silicon is commonly used as an inexpensive detector material in the Vis range. For higher demands, InGaAs is used; it covers the widest spectral range from the Vis to the NIR. We offer silicon carbide as a “solar-blind” detector specifically for the UV range.
-
product
High Output Current Op Amplifiers ≥ 100mA
Analog Devices high speed , high output current (≥100 mA) op amps deliver high output current while driving low impedance loads with excellent linearity. Whether it's high output current, low input bias current, wide bandwidth, high slew rate, or low distortion, no one sets more performance standards for next-generation designs with the widest portfolio of leading edge products than Analog Devices.
-
product
50Hz-100kHz LCR Meter
11022/11025
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
product
USB Picoammeter
9103
Rugged, portable, affordable, and ASCII programmable, RBD's 9103 USB Picoammeter (ピコアンメータ) measures dual-polarity DC current from picoamps to milliamps. It can be biased with an optional built-in fixed +90V DC bias, or your own low-noise DC power supply.
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
Dual Channel, Low-Noise DC Bias Card
PI-41701
The PI-41701 is a dual channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V and features programmable current limits with LED indicators and software interrupt to show/alert the user if the channel is in current limit. This card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output.
-
product
JFET Input Amplifiers
Analog Devices JFET input op amps or FastFET high speed (>50 MHz) input op amps provide high input impedance and ultralow input bias currents for high speed applications. The majority of our FET input op amps feature wide supply ranges from +5 V to 12 V or higher and feature rail-to-rail outputs enabling wide dynamic range.
-
product
Micro probes 1 MHz up to 1 GHz
MFA 02 set
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
Versatile quality control testing system
QuickSun® 550Ei
QuickSun 550Ei is a versatile testing system for qualifying of PV modules with dimensions up to 105 x 205 cm2. Basic set up includes a top class solar simulator which measures modules in sunny side up position enabling e.g. soiling simulations. Several additional measurement methods can be integrated to the same system including high resolution EL imaging with analysis software from one of the most recognized EL system suppliers. Also hot spot revealing IR images can be recorded by applying either forward or reverse bias current, and true nA scale leakage current measurements can be performed with sensitive enough instruments.
-
product
Passive Component ATS
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
product
Shunt Voltage References
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
product
Low Input Bias Current Op Amps (≤100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
product
Low Input Bias Current Amplifiers (<100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
product
SQUID Electronics
XXF-1
It is designed to satisfy the needs of nearly all low-Tc SQUID applications. Additional integrated current sources provide e.g. bias current and calibration pulses for TES applications. These current sources together with an additional switchable feedback path make two-stage SQUID operation very convenient.
-
product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PXIe-9529
The ADLINK PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ??10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
product
Bias Tees From 0.03 MHz To 85 GHz
Pulsar offers a large variety of bias tees that cover frequencies from DC to in both surface mount and connectorized packages. Many models are available with voltages up to 100 volts and currents up to 8 amps and custom requirements are welcomed. Options include higher voltage and current, higher RF input power and a choice of either an RF connector or a feedthrough connection for the DC input port.
-
product
DC Bias Current Source
DU2020/2030/2040
Delta United Instrument Co., Ltd.
Frequency: 10KHz - 200KHz Veracity:3% + 3 digitsTiming: 0.1 - 999 H, settable 3 1/2 bits LCD Display
-
product
SQUID Series Arrays
The SQUID series arrays are ideal for readout of TES sensors or as amplifier stage for discrete two-stage applications. Integrated bias resistors for TES or two-stage applications reduce wiring complexity. Various arrays with input inductances of 3 to 6 nH, input sensitivities of 17 to 23 µA/Phi0, and a current noise between 5 and 10 pA/sqrt(Hz) @ 4 K are available.
-
product
Military-Style DC Solid-State Relay for High-Current Pulse Load Applications
Part No. M33-2N
The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
DC Bias Current Source
FD1772B
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
product
Software
Current-Voltage Measurement Option
Materials Development Corporation
CSM/Win Systems with an I-V option can measure both MOS and diode structures. For junctions, both forwardand reverse bias curves can be analyzed. Junction ideality factor, series resistance, and reverse saturation current are found. Solar cells can be checked for efficiency. Gate Oxide Integrity of MOS devices can be measured as well.
-
product
Cost-Effective ATE System
PRO RACK ATE
Qmax Test Technologies Pvt. Ltd.
Pro-Rack is a cost effective ATE System, which comes with Modular Structure provision option to improvise and enhance much instrumentation based on the user’s requirements. Basically it is designed to cater to the needs of PCB test and repair depots, keeping in mind the changing PCB technology and the challenges in testing them off-line. It can provide complete PCB test and diagnostic functions for any kind of PCB including the latest very high density complex PCBs with high pin count PQFP, FPGA VLSI chips. AC /DC parametric tests enables testing of the DC parametric of device pins on the edge connector for input bias current, Fan out capacity ,Tri-state leakage currents, AC parametric measurements such as Input / Output Propagation delay Rise time / Fall time to further enhance fault coverage. Pro-Rack is designed with VPC Mass Interconnect adapter with 16 bit fixture ID interface to the UUT through simple clips and probes or through card edge or through a bed of nail test fixture.
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
DC BIAS CURRENT UNIT
3265B SERIES
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
product
PRECISION MAGNETICS ANALYZER
3260B SERIES
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents.