Filter Results By:
Products
Applications
Manufacturers
High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
- Pickering Interfaces Inc.
product
LXI High Voltage Matrix 2-Pole 100x2
60-310-102
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing. The 60-310 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
product
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3605A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
T3 Low & High Voltage Differential Probes
T3 Series
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
Prostat Contact Voltmeter
CVM-780
The CVM-780 contact voltmeter combines the ease of use of a digital voltmeter with the high impedance and low capacitance of a true electrostatic voltmeter, in a small, portable package.It reads the actual voltage, without interference from the electrostatic field strength. The ceramic tips of the probe allow precise measurement of values.Measurement of voltages up to 500 VDC.
-
product
Battery Cell Formation System
17000 series
Chroma 17000 series is specifically designed for the formation of Lithium Ion and Lithium Polymer secondary batteries. The 17000 series is a complete turn-key system, including carrier trays, robust battery probe contacts, high quality charge/discharge modules and intuitive software all under computer control. Patented Battery Voltage Tracking (BVT) DC-DC conversion power modules minimize power consumption in battery charging, and Energy Recycle Modules (ERM) recycle the discharged energy directly back to the DC power system for increased power efficiency. These power saving designs provide a planet friendly solution along with cost savings by reducing energy consumption. The intuitive software provides a flexible selection in the charge/ discharge channel, current rating, and modules under test. These features allow the Series 17000 to be used for final cell development, pilot line production, high volume production and ongoing reliability monitoring/quality control.
-
product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
product
High Voltage Optically Isolated Probes
High Voltage Optically Isolated Probes are designed to aid in device characterization measurements. Whether it is low or high voltage signals sitting on HV busses, high bandwidth, extreme precision, and optical isolation means floating measurements are easily made with minimal DUT loading.
-
product
Active Differential Probe
DF-600
The DF-600 Differential Active Probe is a high input impedance and low input capacitance probe. It also supports extremely high frequency bandwidth, and high voltage input. It is designed using three OP amps, namely two FET buffer OP amps and a low offset OP amp. Therefore, even with long-term operations, the measured voltage will not drift. The voltage offset always approach 0 volts. (USB power supply should be 5V ±2%). The following diagram shows the circuit of DF-600.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Insulation Resistance Tester For PV (Judge Deterioration Point)
MIS-PVS
MULTI MEASURING INSTRUMENTS Co., Ltd.
The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
400 MHz High Voltage Passive Probe
HVP120
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
High Voltage Probe
PL-10
*MODEL:PL-10*IMPEDANCE:1.111MΩ*ACCURACY: ±0.25%*FREQUENCY B.W.:DC~50MHz*WORKING POWER:MAX. 1Watt*INPUT VOLTAGE:MAX.250VDC or 200V rms AC*DIMENSION:46mm(L)xΦ16mm(D)*WEIGHT:25g
-
product
Multimeter Test Probes
Multimeter Test Probes, Voltmeter test leads,with the Parrot™ Clip Invention provide precise, HQ, accurate, reliable contacts and connections. Parrot™ Clips with HQ leads and banana plugs or other connectors are the best solution for DDM, analog multimeter for high voltage measurements as well as for high current measurements. Measurements with multimeter test probes require both: Hands-on direct point contact and grip on, Hands free removable connection.
-
product
Optical Voltage Probe
400-02
Srico’s optical voltage probe uses advanced, proprietary optical chip technology to achieve precise, interference-free measurement. Our sensor and optical fibers are made of dielectric materials. This facilitates a high degree of isolation between the voltage test point and the instrumentation system ⎯ at a safe distance of 100 meters and more. This system senses, measures, and transmits electrical data very accurately.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
product
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Acute High Voltage Differential Probe, 50x/500x, 100MHz, 3500V
ADP5100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Digital Teslameters/Gaussmeters
S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.
-
product
Low Voltage Differential Oscilloscope Probes
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
-
product
2kV, 400 MHz High Voltage Differential Probe
HVD3220
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Hi-Z Probes
B-1012-B
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
High Voltage Optically Isolated Probe, 1 GHz Bandwidth. Includes soft-carrying case.
DL10-ISO
The DL-ISO enables highest confidence in GaN and SiC device characterization with highest accuracy, best signal fidelity, and comprehensive connectivity.
-
product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation