Filter Results By:
Products
Applications
Manufacturers
- Taylor Dynamometer, Inc.
product
Display-Only Dynamometer Testing Instrument
DynTek-PC
The DynTek-PC for engine dynamometers is a display-only system intended for basic engine dynamometer testing requirements. This system provides for the measurement of torque in either tension or compression (both clockwise and counter-clockwise engine rotation) and speed from a standard Magnetic Pickup. The system is designed to set on a table or desktop near the PC.
-
product
Instrument Transformer Testing
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
product
Portable Analog Instruments
Instrument transformer is a general term for voltage transformers and current transformers that are used with electrical instruments. The main purpose of instrument transformers is to extend the measurement range for electrical quantities (voltage, current, power, power factor) on large-current and high-voltage circuits. They serve to convert currents and voltages to levels that are suitable for measurement, and to insulate the instrument, etc. from high-voltage circuitry.
-
product
Precision LCR Meter (20Hz to 1MHz)
ST2827
ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.
-
product
Power Transformer
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
product
Test Equipment for Instrument Transformer
is desirable for measuring ratio errors and phase angles of low current (voltage) transformers used in electric devices, such as watt hour meters, smart meters, digital current meters, and transducers, etc.
-
product
Step Up Transformer
MagD
SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.
-
product
Transformer Polarity Checker
865
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
product
Transformer Tester
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
product
Digital Tap Position Indicator With Voltage &Counter Display
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.
-
product
Portable Partial Discharge/ Detection
AE-150
The AE-150 is designed to detect and localize Partial Discharge activity inside oil-insulated power transformers. This instrument is a powerful diagnostic tool that combines electric and acoustic sensing technologies to perform partial discharge pinpointing.
-
product
Transformer Turns Ratio Meter
TTRM 302
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
Current Transformer Analyzer
CT Analyzer
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
product
Instrument Transformer Calibrators
MRL 22
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Instrument Transformer Calibrators
MRL 11
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
Oil Resistivity & Tan Delta Test Set-Up
This testing set is an automated instrument, widely used for measuring electrical characteristics of insulating liquids, transformer oil and other insulating material samples.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
High-Voltage Test Device
PGK 110 / 5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing as DC or Dc testing device* Polarity of the DC voltage can easily be reversed* Robust and durable
-
product
Test Switches and Accessories
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
product
CT/VT Test System
Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.
-
product
Transformer Testing Instruments
Wuhan Huatian Electric Power Automation Co., Ltd.
Transformer Testing Instruments by HVTEST
-
product
TD Guard
TD Guard Intelligent Sensor is an on-line CONTINUOUS Capacitance and tan-δ monitoring system for transformer bushings. TD Guard Intelligent Sensor is the first and only instrument on the market providing absolute Tan-δ measurement in on-line permanent monitoring of transformer bushings, granting the best level of diagnostic leverage and reliability. Sensitivity better than 10-4.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
Instruments Transformers Tester
Calport 100 Plus
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
product
On Load Tap Changer Analyzer
TAP4
The TAP-4 is the first instrument to use vibro-acoustic measurement to perform tests on On-Load Tap Changers (OLTC). The TAP-4 is a universal device, it adapts itself to any type of transformers: MR Reinhausen, ABB, Ferranti, Federal Pioneer and others.
-
product
Instrument Transformer Comparator
PMT20010
Power Measurement Technologies Inc.
The PMT20010 Comparator is an automatically balancing bridge that measures the accuracy of instrumentation potential and current transformers.
-
product
HIPOT Insulation Testers
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.
-
product
ANSI Potential Transformer Burdens
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.