Filter Results By:
Products
Applications
Manufacturers
Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Integrating Sphere Spectroradiometer System for LED
LPCE-2(LMS-8000)
LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.
-
product
Target Wheels
Santa Barbara Infrared manufactures a wide variety of standard and custom target wheels, to conveniently and accurately position multiple targets in front of a blackbody source. The SBIR 300 Series Target Wheels are specifically designed to be used with SBIR’s standard differential blackbody sources and integrating sphere light sources. These motorized target wheels are available in several standard models to accommodate different sizes and numbers of targets.
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
product
*Pulse Characterization Sensors
Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω
-
product
IR/Visible Target Projectors
Santa Barbara Infrared’s reflective infrared and visible target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) and visible imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies, Infinity VSX Integrating Spheres and 300 Series Target Wheels.
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
Integrating Spheres - Luminous Flux Measurement For LEDs And Lamps
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.
-
product
Integrating Sphere Solutions
An integrating sphere is a light collector which takes advantage of physical geometry to homogenize any radiation being emitted inside by relying on a high-reflectance coating material. Depending on the wavelength range the end user using a sphere with, different coatings have different advantages based on the application.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
Detectors
Thorlabs' photodetectors are capable of detecting light throughout the UV, VIS, NIR, IR, and THz spectral regions. Our photodetectors feature sensors that enable properties such as intensity, power, intensity distribution, wavefront shape, energy, and wavelength to be measured. We offer unmounted photodiodes as well as amplified, biased, and avalanche photodetectors. Thermal power detectors are available unmounted, mounted on a PCB, or mounted on an aluminum plate. Also available are position-detecting sensors, integrating spheres, and an acoustic detection module.
-
product
Integrating Spheres For UV
Konica Minolta Sensing Americas, Inc
Instrument Systems offers complete measurement solutions for UV-A, -B and -C radiation starting from 200 nm. The operation of the well-proven Instrument Systems spectroradiometers, e.g. CAS series, with integrating spheres made from PTFE facilitate high sensitivity measurements of UV radiant flux.
-
product
Transmission & Integrating Sphere FT-NIR Spectrometer
QuasIR™ 4000
The QuasIR™ 4000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
UV-Vis & UV-Vis-NIR Systems
Our range of powerful and productive UV-Vis and UV-Vis-NIR molecular spectroscopy systems offers options for any optical application. The Cary 60 Spectrophotometer has a unique Xenon flash lamp to enable remote sampling, while the Cary 4000 allows you to measure highly turbid solutions without an integrating sphere. The Cary 8454 photodiode array captures the complete UV-Vis spectrum (190-1100nm) in less than one second.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Integrating Spheres
IS-*M
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
product
Spectroradiometer
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Quick-Scan Spectrophotometer Colorimeter
LMS-5000
LMS-5000 Quick-Scan Spectrophotometer Colorimeter is a very widely applied single monochromators spectrophotometer with high accuracy. A typical measuring time during the spectral range from 380~800nm is less than 10 seconds. LMS-5000 used with right size integrating sphere and standard light source can be applied to do spectral measurement of LEDs, LED modules, CFL, Fluorescent Lamp, CCFL, HID lamps and other luminaries.
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
High Accuracy Spectrophotocolorimeter
LMS-3000
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
product
UV-VIS Spectrophotometer
UV-i Selection
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Reflection Meter
RC-088
This instrument is a special equipment for measuring the reflectivity of rearview mirror (or similar product) of motor vehicle. The product composes intelligent measuring instruments, optical integrating sphere, parallel lamp, standard light source, constant current source etc. It is easy to operate,it can measure the reflectivity quickly and accurately. On instrument structure, it adopts standardized modulation design. It takes latest single chip as its digital central processing element. After the measuring signal is converted by modulus, CPU will do some computation and compensation. The instrument can display the reflectivity of device which is measured in rear time. It operates simply and quickly, the indication is direct and accurate. It’s good for quality examination &control in the production scene as well as laboratories. This product has the convenience &quick demarcation way, can meet requirement of different occasion. It is applicable for measuring light reflection on mirror and not mirror parts.
-
product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.