Filter Results By:
Products
Applications
Manufacturers
PD
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge, Partial Discharge Detection, Partial Discharge Monitors, PD Test, Partial Discharge Test
-
product
Online PD Spot Tester
Liona
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
product
PD free AC Hipot Test Set
FPA Series
FPA Series test sets perform field or factory testing on larger electrical apparatus, including motors & generators, switchgear, bushings, bus duct, etc. This series offers the higher kVA ratings needed (0-6/12 kV AC @ 6 kVA), but is still packaged for portability.
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
Battery Cell Insulation Tester
Chroma 11210
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
product
Tap Adapter
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
product
USB PD Power Supply/Module ATS
8000 Series
The USB 3.1 specifications has three major features which are 10Gbit/s transmission speed, USB PD (Power Delivery) with support for 100 watt charging power, and the standard Type-C connector/cable that can be inserted with either side. It is expected to meet all kinds of data / video transfer applications. The advent of USB PD may consolidate the specifications of various power converters and the laptop, monitor, printer or Hub that implements USB PD is no longer a simple power-consuming device but able to supply power to other devices. The USB PD DRP (Dual role port) function allows the built-in USB PD module to deliver a maximum of 100 watts of power through the Type-C interface. To make sure the USB PD Type-C output power does not supply invalid voltage or poor power output characteristics with excessive noise that can damage the power consuming device and cause unsuccessful startup, each USB PD power supply or module has to be fully tested during production to ensure the product features meet the design specifications. This ensures high-quality products are provided to the market to gain acceptance.
-
product
VLF Testing and Diagnostics System
PHG 80 TD/PD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltage* Compact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models
-
product
Software for the Development and Implementation of Test Programs using IEEE 1641
newWaveX Suite
We Have a unique suite of tools to support the development and implementation of test programs created using IEEE 1641 to define the signals and tests. These include the entry-level version of newWaveX (newWaveX–Lite), the development versions of newWaveX (newWaveX–SD and newWaveX–PD) and the complete integrated development environment for IEEE 1641, SigBase. These tools provide everything necessary to work with IEEE 1641, from creating simple signals through to implementing and managing a complete 1641 test environment. All of our 1641 tools are commercial off-the-shelf (COTS) items that may be used stand-alone or integrated into a complete test development environment. newWaveX products may be integrated with third party test executives and associated software.newWaveX is an intuitive user-friendly suite of products that does not require specialist training for users to acquire the skills to develop 1641 programs. Completing the IEEE 1641 User/Developer training course (which uses newWaveX Signal Development for the hands-on element), together with the associated 1 day newWaveX–SD User/Developer training course, provides complete information for the newWaveX user. Further support is provided for users of newWaveX packages under the maintenance agreements for those products.
-
product
PD Test Systems
1. Number of channels: 2/4 electric signal interfaces & 1 EXT interface 2. Sampling frequency: maximum 200MGa/s 3. Sampling precision: 12bit 4. Range: 0.1mV~20V 5. Range switch: 1mV, 2mV, 5mV, 10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V 6. Frequency band range: 1Hz-60MHz 7. Range non-linear error: 5% 8. Range of capacitance for test object: 6pF~250µF 9. Power source mode: internal lithium cell / AC 220V 10. Display: 6.5 inches TFT LCD 11. Resolution: 640×480 12. PV: 4GB 13. Hard disk: 32G stiff disk used for storing the test data
-
product
Play Detectors - Lift Mounted
Approved for ATL and one man testing, Boston hydraulic play detectors lead the field with more features and benefits than any other unit available on the market. Compared to some, a Boston PD provides substantially more force, extra moving-plate travel and a larger plate area.
-
product
Electric Vehicle AC Charging Compatibility ATS
8000
It is a customized system for Electric Vehicle AC Charging Compatibility testing.Hardware : Integrated by AC Source/Power Meter/DC Source/Function Generator/Scope/ EVSE CP & PD Simulator…。Software : Fully complies with SAE-J1772, CNS15511 test requirements
-
product
Cable Diagnostic Tools
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
product
PoE Tester
PE-100
The PoE Tester/Power Monitor is designed for testing standard PoE and measuring power of PoE systems, by performing both PSE (Power Source Equipment) detecting and PSE/PD (Powered device) inline testing. Compliant with IEEE802.3 af, 802.3at standard and 802.3bt ultra 4-pair up to 60W-100W. PSE detecting display PoE type (af or at), power source (Endspan or Midspan) and perform a load test for voltage drop with REV LED indicates a reversed power. Inline PSE/PD testing-measure and display in rotation between voltage (Volts), current(Amps) and power(Watts) via dual 4 digit 7 segment LEDs which provides voltage available, current flowing and how much power an PD actually need ensure sufficient power for PD to make the PoE is sustainable.
-
product
Universal AC-DC Power Supplies
PS-WT24-48-US
The PS-WT24-48-US is a small, convection cooled, 24W power supply for use with WINSYSTEMS’ Power over Ethernet (PoE) boards. The unit can be used as a power source for Power Sourcing Equipment (PSE) devices or auxiliary power input for Power Devices (PD). It is a universal design that accepts 90 to 264VAC input and generates up to 0.5A of current at +48 volts.
-
product
Measurement Of Surface Tenison Using The Pendant Drop Method
SURFTENS PD
Optik Elektronik Gerätetechnik GmbH
SURFTENS PD is an image processing software for measurement of surface tension of liquids by pendant drop method. By help of drop shape analysis the surface tension is calculated, using the form parameters of the pendant drop. SURFTENS PD is used in connection with OEG equipment, but also available as standalone solution for applications of customer.
-
product
Partial Discharge Inductor
Tracy
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
product
Rapid PSE And Chained Data Test Of 4-Pair And 2-Pair PSE's
PSL-3424 Quick Test for 802.at and 802.3bt PSE's
*Accessible from PSA Interactive or PowerShell PSA*Scans 2 to 8 PSE ports per test cycle*Automatically determines and adapts to PSE maximum assigned class*Tests PSE’s that grant full power via PD Classification or through PoE LLDP*Validates PoE Detection Acceptance and Rejection Range*Measures PSE Port Voltage at both minimum (DC MPS) and maximum (Pclass) load conditions*Reports PSE type (AT vs BT), maximum assigned class capability, and Pclass power capacity*Assesses Disconnect Power Removal response*Assesses Overload Power Removal response*Assesses LLDP Power Protocol and Allocations (PSL-3424L)
-
product
PMA Suite For The PSA/PSL-3000: 802.3at (30W) PSE's
*In-Depth System Testing of 802.3at and 802.3bt 2-Pair PSE's Using PSA-3000 or PSL-3000 instruments*Concurrently Analyze Up To 192 PSE Ports*Robust Emulation of Type-1, Type-2, and Type-3 (Class 4) PD's Including PoE LLDP*Assess PSE Power Administration Decisions*Assess PSE Power Management Behaviors*Static and Transient Reserve Capacity Analysis*Per-Port Variation and Uncertainty Analysis*Assess PSE Power Reliability Over Time*Colorful and Graphical Pop-Up Spreadsheet Reporting*Available to PSA-3000 and PSL-3000 as part of the Live PD Emulation license feature
-
product
Gas-Filled Hv Testing Transformer
GTU-300KVA/600KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
product
Portable Switchgear Partial Discharge
PD-SG1
The PD-SG1 is a dual transducer Switchgear PD detection instrument. The unit detects TEV signals generated by internal discharge, as well as acoustic discharge generated by surface tracking or corona.
-
product
USB PD Test System
6050
Single Output USB PD USB PD basic version:the single-group test systemarchitecture is as shown in the table, 5302A AC Source, 3302F + 3310F series and9922-R Quick Charge Controller.
-
product
PD Conformance Test Suite
Sifos Technologies offers the ultimate simplicity in testing a PD’s conformance to IEEE 802.3 Standards with Pass/ Fail reporting in the PD Conformance Test Suite available for purchase with the PDA-600 Family of Instruments.
-
product
Partial Discharge Tester
19501-K/19500
Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.
-
product
VLF Testing and Diagnostics System
PHG 70 TD/PD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate * individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltageCompact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models
-
product
PDBase II
Even very skilled operators will find hard to make a diagnosis, in situations as the one mentioned above, through a mere visual evaluation of the pattern graph . Techimp new technology bases itself on the principle that efficient separation and identification of PD data can be achieved collecting PD pulses themselves and not only, as digital instrumentation commonly available does, PD pulse peak and phase.
-
product
PoE Service Analyzer
PSA-3002-SA
Comprehensive Assessment of 2-Pair (802.3at) PoE Service at Any PD Outlet. The only PoE Service Tester built on Sifos PowerSync® Analyzer technology.• Analysis and Troubleshooting for All Standard 2-Pair (802.3at) PoE Installations Including Type-2, LLDP Power • Provisioning• Fully Verify Interoperability of PoE Service to the PD• Verify PoE Service Safety Features• Assess Continuous Power Delivery at the PD by PD Class• Assess Transient Power Delivery at the PD• Troubleshoot Intermittent PoE Service Problems• Colorful Microsoft Excel Reporting• Portable Instrument with Rugged Carrying Case
-
product
LLDP Emulation And Analysis
802.3at and 802.3bt PD Emulation and Protocol Analysis
*Integrated PoE LLDP and Load Emulation in a Single Instrument*IEEE 802.3at and 802.3bt LLDP Compliance Analysis*Independent, Per-Port 802.3at and 802.3bt LLDP Emulations*Flexible Single and Dual Signature PD LLDP Emulations*One-Click LLDP Protocol Capture and Analysis*Pop-Up Excel Spreadsheet Reports Assess Protocol Content and Timing*Enables One-Click Emulated Power-Ups and Standard Waveforms with LLDP Power Granting PSE's*Enables 2-Pair and 4-Pair PSE Conformance Test Suties with LLDP Capable PSE's*Enables 2-Pair Multi-Port Suite with LLDP Capable PSE's*Available for PSA-3000 and PSL-3000 Platforms
-
product
Partial Discharge Testing Equipment
AR700
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
product
Diodes
Development target specification*PD=5W class*Capability for load dump surge:ISO7637-2, JASO A-1*Reliability standard:AEC-Q101*Package size:[W×L×H] 12.0×9.6×4.3(mm)
-
product
*Laser Photodiode Sensors
Photodiode sensors have a high degree of linearity over a large range of light power levels: from fractions of a nanowatt to about 2 mW. Above that light level, corresponding to a current of about 1 mA, the sensor saturates and reads erroneously low. Therefore, most Ophir PD sensors have a built-in and removable attenuator allows measurement of up to 3 W without saturation.