Filter Results By:
Products
Applications
Manufacturers
- Virginia Panel Corporation
product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, .025" Round Post
610138115
Primary mating contact 610138200. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body (RCV) – BeCu (Twin Female)BeCu/PhBrz (Crimp)Male (ITA) – BrassContact Plating Female (RCV) – 50µ” Au over 100µ” NiMale (ITA) – 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
Single Channel USB Programmable Instrumentation Amplifier
USBPIA-S1
The USBPIA-S1 stand alone USB controllable module provides a single channel of high-quality instrumentation amplifier and optional AC coupling, for front-end signal conditioning compatible with all popular A/D converter devices. The USBPIA-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPIA-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPIA-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
product
Servo-Pneumatic Asphalt Testing System
All signal conditioning, as well as high-speed data acquisition and control functions are done by the unit and graphically interfaced through CATS, windows based software running on a standard PC. The system is capable of performing the full spectrum of HMA tests: dynamic complex modulus, flow number, flow time, indirect tension, beam flexural fatigue and resilient modulus. These tests are done with the appropriate testing modules. The different testing modules can be obtained after the initial system acquisition at the same discounted price. In addition, guarantees system upgrades in order to meet future standards .
-
product
Interface Panel for SLSC
THROUGHPOINT™
Bloomy's ThroughPoint™ Interface Panel provides a simple, yet highly-flexible connection between the unit under test and resources in a National Instruments Switch/Load/Signal Conditioning (SLSC)-based test system.
-
product
Crosspoint Switches
Macom Technology Solutions Holdings Inc.
At MACOM we offer the industry’s largest portfolio of low latency crosspoint switch devices with channel counts ranging from 2x2 all the way up to 288x288, and data rates from 3.2 Gbps to 28 Gbps. Our devices are equipped with signal conditioning technology that enables system designers to use lower cost board materials and components while increasing their system margin.
-
product
High Elongation Extensometers
Model 3800
Jinan Testing Equipment IE Corporation
The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
32-CH 12-Bit 100 kS/s Isolated Analog Input Card
PCI-9113A
ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.
-
product
Data Acquisition and Control System
DAQ 7000
data acquisition and control system that provides connectivity, signal conditioning and modular I/O for variety of sensors or signals, and it is an ideal DAQ for field deployment.
-
product
Tactical Grade Inertial Measurement Unit (IMU)
ADIS16490 iSensor
The ADIS16490 iSensor® device is a complete inertial system that includes a triaxial gyroscope and a triaxial accelerometer. Each inertial sensor in the ADIS16490 combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyroscope bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measurements. The ADIS16490 provides a simple, cost-effective method for integrating accurate, multiaxis inertial sensing into industrial systems, especially when compared with the complexity and investment associated with discrete designs. All necessary motion testing and calibration are part of the production process at the factory, greatly reducing system integration time. Tight orthogonal alignment simplifies inertial frame alignment in navigation systems. The SPI and register structure provide a simple interface for data collection and configuration control.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
Sensor Signal Conditioning System
SCS
SCS Sensor Signal-Conditioning System complements the iDSC 1816 anti-aliasing board to provide a continuous path in a single package: starting with raw measurements at the sensor and ending with conditioned anti-aliased data logged to disk on a PC.
-
product
System Integration
G Systems develops fully integrated systems and we know that both software and hardware are equally important to system design. Our focus on code quality and optimization ensures customers receive efficient and maintainable code. We specialize in LabVIEW development and all of our LabVIEW developers are certified developers or architects. We’re also highly skilled in mechanical and electrical hardware design and builds on a wide variety of data acquisition, signal conditioning, RF, and distributed communication platforms.
-
product
Large Electrical Machines Bench Testing
The automated system for recording parameters during testing of gas turbine generators consists of several independent but interacting measuring subsystems and a signal conditioning system. The subsystems for recording "fast" signals are implemented on the PXI platform, "slow" signals are registered by a subsystem built on the basis of the Compact FieldPoint platform.
-
product
Displacement Transducers - DC Operation
Columbia Research Laboratories
The Columbia DDCP Series Transducers are completely self-contained displacement measurement systems that operate from a low voltage DC power supply or battery. They permit highly accurate readout and recording of an output signal directly without auxiliary signal conditioning electronics.
-
product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
product
PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781345-01
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
3-CH RTD Input Module
ND-6013
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Bluetooth Enabled Signal Conditioners I/O Modules
microBlox
Acromag's microBlox uB Series I/O modules offer a compact, high-performance solution for interfacing sensors and field devices with data acquisition systems. uB signal conditioning modules are ideal to isolate, filter, convert and amplify a wide variety of signal types for test, measurement and control systems. Just plug uB modules into 4, 8, or 16-channel backpanels in any mix for a high-density analog I/O interface. Channel-to-channel isolation provides optimal noise and surge protection from ground loops, spikes, and high common mode voltages.
-
product
4 Channels of Strain Gauge Inputs for the SCS-800 Signal Conditioning System
SCS-817
The SCS-816 and SCS-817 amplifier/filter module provides eight 8-pole low-pass filters that can be individually configured for a cutoff-frequency from 0.5Hz to 70kHz(SCS-816) and 0.5Hz to 60kHz(SCS-817). Each of the SCS-816/SCS-817's eight channels features an instrumentation amplifier with software-selectable gains of 1 to 1000 in 1-2-5 steps.
-
product
Titan Data Acquisition
DAQ
Titan Data Acquisition (DAQ) Systems offer universal signal conditioning, low power consumption, convenient SD card storage, and easy-to-use software. Systems can be purchased as a complete test kit, including custom cables and accessories. Titan products are designed and built in the US.
-
product
Engineering/Development System
ULTRA L
The ULTRA L is a high performance “Lab” system that provides thermal conditioning, mechanical stimulus and an electrical ATE signal path for testing Micro-Electro-Mechanical Systems (MEMS) Accelerometers and Gyroscopes.
-
product
Miniature Axial Extensometers
Model 3442
Jinan Testing Equipment IE Corporation
Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.
-
product
2-Channel Front End
BEQ II.1
*Binaural, digital equalizer with 24 bit technology and USB interface.*The digital equalizer BEQ II.1 combines the characteristics of an equalizer, a two-channel front end and an A/D converter into one mobile and very versatile measurement tool.*Binaural, aurally-accurate recordings can be conducted easily with BEQ II. The AES/EBU interface allows a quick and easy expansion into a four-channel system, e.g. with the HMS III or HMS IV. Via the ADAT interface, up to four BEQ II units can be connected, allowing for eight-channel recordings.*Integrated signal conditioning allows common measurement sensors (Microphone, Line, ICP�) to be directly connected to the front end. In addition, separate pulse inputs are available e.g. for RPM data acquisition.*Thanks to the high-performance built-in battery - external DC power supply is also possible - and its low weight, BEQ II.1 is the ideal tool for either mobile or stationary operation.
-
product
Programmable Anti-Alias Low-Pass Filter and Instrumentation Amplifier
USBPGF-S1
Single Channel USB Programmable Anti-Alias Low-Pass Filter and Instrumentation Amplifier for Signal Conditioning in Data Acquisition Systems. Differential or single ended input. 10Vmax Signal Input and Output with input protection up to 40V. Software-programmable instrumentation amplifier gains of 1 to 1000.
-
product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Fracture Mechanics Clip-On Gages
Model 3541
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
RS-422/RS-485 Repeater
ND-6510
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
6000 Series Analog I/O Modules
Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.
-
product
Data Aquisition System
KiDAQ
KiDAQ is an innovative, general purpose data acquisition system (DAQ) to measure more than 20 different analog and digital signal types. The wide selection of signal conditioning and data acquisition modules enables perfectly fitted system configurations, exactly to the customer’s requirements. Thanks to its modular design and various case types, KiDAQ can be used in a broad range of applications. Depending on your use case, you can choose from a variety of product designs for laboratory applications, permanent installations and mobile use.