Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI 16x SPST High Voltage Reed Relays
40-310-101
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
Precision Current Preamplifier
SIM918
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
Current Sensors
Our current sensors were designed for a simple, customer-specific construction of niobium wire wound magnetometers, gradiometers or preamplifiers for small current or voltage signals.
-
product
Low-Noise Voltage Preamplifier
SR560
Stanford Research Systems, Inc.
The SR560 is a high-performance, low-noise preamplifier that is ideal for a wide variety of applications including low-temperature measurements, optical detection, and audio engineering
-
product
BJT Voltage Preamplifier
SIM911
Stanford Research Systems, Inc.
The SIM910 and SIM911 are low-noise, programmable preamplifiers which are ideal for a wide range of small signal applications. The primary differences between the two models are their input impedance and input noise.
-
product
JFET Voltage Preamplifier
SIM910
Stanford Research Systems, Inc.
The SIM910 and SIM911 are low-noise, programmable preamplifiers which are ideal for a wide range of small signal applications. The primary differences between the two models are their input impedance and input noise.
-
product
Multi Channel Analyzer
BOSON
Baltic Scientific Instruments, Ltd
Spectrometric device BOSON acquires and displays spectra with overlapping by energy up to 1000 timesNo resolution deterioration at operation in the beginning of spectrum energy rangeStable operation with preamplifiers of TPR type with output voltage swing up to +/- 10 V and reset duration up to 250 usAutomated P/Z adjustmentImproved dead time correctionSoftware-based spectrum stabilizationSetting and control of all parameters using colour LCD display with touch screenComplete remote control of Boson via software on PCAuto BLRAnalogue time dependent shapingSpectrum stabilizationDead time correctionOperation with preamplifier TPR
-
product
Low Noise Voltage Preamplifier
1201
The Model 1201 Voltage Preamplifier with Remote Gain Programming Option (06) is usable in both computer controlled and maual applications requiring uncompromising performance.
-
product
Preamplifiers
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
product
The Golden STM
*Golden (chemically resistive) vibration isolated STM body with implemented preamplifier*Computer with PCI board based SPM controller *Anfatec Scan & Anfatec Present*19“ STM controller (extra low noise 24 bit converters)*HV display for z-direction*High voltage amplifiers for the x-y-tube scanning*Optional: PC controlled bi-potentiostat and electrochemical cell
-
product
Power modules
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
product
LISN & Voltage Probes
All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.
-
product
1 MHz Bandwidth Voltage Preamplifier with Bandpass Filter
EC6081 mk2 - preamplifier
The EC6081 mk2 (VP2000) is a 1MHz bandwidth voltage preamplifier with bandpass filter that is designed for uses in conjunction with piezoelectric hydrophones. VP2000 offers excellent low-noise performance over the entire frequency range; and adjustable gain selection. A range of 12 high-pass and 12 low-pass filters are available, these allow ideal band pass filter settings.
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
Electronic Instruments
The ORTEC range of modular electronics includes instruments in NIM formats as well as other modular instruments, such as photomultiplier bases, preamplifiers and other accessories. ORTEC also offers modular instruments for pulse height spectroscopy, fast timing, counting, high voltage power supplies and other special functions.
-
product
AC-Powered, AC Voltage Monitor
VAA/VQA
NAI’s VAA and VQA are AC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
product
Lock-In Voltage Preamplifier
SR552
Stanford Research Systems, Inc.
The SR552 Voltage Preamplifier is designed to work with SRS lock-in amplifiers, providing gain where it is needed most?right at the experiment. The preamplifier minimizes noise and pickup in the connecting lines and can reduce measurement time in noise-limited experiments.
-
product
DC-Powered, AC Voltage Monitor
VAD/VQD
NAI’s VAD and VQD are DC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
product
Linear Array Detector Cards
X-Card 0.2 to 2.5mm
A product family of high performance linear X-ray detector cards with preamplifier ASICs. The preamplifier ASIC converts the charge output from the photodiode array into voltage with serial output for easy integration with readout electronics. Can be arranged end-to-end to form large linear detector arrays.
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
Preamplifiers
Preamplifiers recognize the extremely low amplitude AE signal produced from AE sensors, and convert the signals into amplified and usable forms. As applications and testing conditions vary, project needs may change as well. Physical Acoustics offers an entire line of preamplifiers for a variety of testing requirements. Operating in conjunction with our specialized AE software, preamplifiers also moderate signal size during the data collection process, helping to produce accurate results.
-
product
Pre-Amplifiers
MPR, MDA series
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
product
Low Noise Differential Preamplifiers
Provide a high gain amplification to 1MHz with an AC output derived from a very low noise FET instrumentation amplifier. Each model has fixed gain settings of x1 (0dB), x10 (20dB), x100 (40dB) and x1000 (60dB) over a selectable bandwidths of 100Hz, 1kHz (HP), 3kHz, 30kHz, 100kHz and 1MHz (7000 model only). Noise referred to input is 7nV√Hz and common mode rejection is >100dB at 1kHz. Momentary pushbutton switches are provided that control coupling, bandwidth, gain and channel on/off selections. BNC connectors are provided for single-ended and differential input, ac output, and dc output (optional) connections.
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Accelerometer with Built-In Preamplifier
NP-3000 series
This sensor converts mechanical vibrations into electric signals in proportion of vibration acceleration."The NP-3000 series offers ultra-small masses of 0.4g, tri-axial type which can obtain vibration directions of XYZ at once, waterproof, high sensitive type, and so on. You can choose the most suitable detector according to the purpose of use, operation conditions, and applications. Since the preamplifier is built in the detector main body of the NP-3000 series, sensor signal input part can be made relatively inexpensively and it can be directly connected to analysis equipment such as our FFT analyzer."
-
product
Current Preamplifier
1211
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes